Back << Power Limited Circuit Cable Type PLTC >> Printer Friendly Page

UL 2464 NEC Article 725 CSA PCC

       
NOM. INSUL. THICKNESS
NOM.
JACKET
THICKNESS
NOMINAL
DCR
OHM/Mft
NOMINAL
CAP.
pF/ft
CATALOG NUMBER
NO.
OF COND.
AWG
SIZE
COND STRAND
Inches
mm
Inches
mm
COND
SHLD
A
B
C0550
2
22
7/30
0.015
0.38
0.037
1.07
0.236
7.47
32.0
57.6
C0551
3
22
7/30
0.015
0.38
0.037
1.07
0.271
7.85
29.0
52.2
C0552
4
22
7/30
0.015
0.38
0.042
1.07
0.311
8.56
29.0
52.2
C0553
6
22
7/30
0.015
0.38
0.042
1.35
0.360
10.62
26.5
47.7
C0554
9
22
7/30
0.015
0.38
0.053
1.35
0.442
12.19
26.5
47.7
C0560
2
18
16/30
0.015
0.38
0.042
1.07
0.306
9.17
40.0
72.0
C0561
3
18
16/30
0.015
0.38
0.042
1.35
0.355
10.24
33.5
60.3
C0562
4
18
16/30
0.015
0.38
0.053
1.35
0.417
11.18
33.5
60.3
C0563
6
18
16/30
0.015
0.38
0.053
1.35
0.485
13.18
30.5
54.9
C0564
9
18
16/30
0.015
0.38
0.063
1.60
0.569
15.80
30.5
54.9

A - Capacitance between conductors.

B - Capacitance between one conductor and other conductors connected to shield.

Conductor color: 1 through 9 pairs - black, red

These cable products can be cut to length, jacket removed, and conductors stripped to custom specifications